Search results
Results from the WOW.Com Content Network
The two lower valves are called the master valves (upper and lower respectively). Master valves are normally in the fully open position and are never opened or closed when the well is flowing (except in an emergency) to prevent erosion of the valve sealing surfaces. The lower master valve will normally be manually operated, while the upper ...
Valves can be categorized into the following types, based on their operating mechanism: Ball valve, for on–off control without pressure drop. Ideal for quick shut-off, since a 90° turn completely shuts off, compared to multiple 360° turns for other manual valves; Butterfly valve, for on–off flow control in large diameter pipes
There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.
A common type of this style fitting is a "hex bushing" with a hex head for installation with a pipe wrench. A double-tapped bushing is more compact than a reducer but not as flexible. While a double-tapped bushing has a more minor female thread concentric to a larger male thread (and thus couples a smaller male end to a larger female), a ...
Two block valves and a bleed valve are as a unit, or manifold, to be installed for positive isolation. Used for critical process service, DBB valves are for high pressure systems or toxic/hazardous fluid processes. Applications that use DBB valves include instrument drain, chemical injection connection, chemical seal isolation, and gauge isolation.
Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...
A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.