enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    There is a likelihood that underfloor heating may add to offgassing and sick building syndrome in an environment, particularly when the carpet is used as flooring. [citation needed] Electric underfloor heating systems cause low frequency magnetic fields (in the 50–60 Hz range), old 1-wire systems much more so than modern 2-wire systems.

  3. Wet-bulb temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_temperature

    The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.

  4. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    The ground floor with a slab on grade has less temperature rise compared to middle and top floors, and an increase of the supply air temperature causes a decrease in the temperature rise. The temperature rise is not significantly affected by the perimeter zone orientation, the internal heat gain and the window-to-wall ratio. [16]

  5. Wet-bulb globe temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_globe_temperature

    The wet-bulb globe temperature (WBGT) is a measure of environmental heat as it affects humans. Unlike a simple temperature measurement, WBGT accounts for all four major environmental heat factors: air temperature, humidity, radiant heat (from sunlight or sources such as furnaces), and air movement (wind or ventilation). [ 1 ]

  6. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    The study indicates that stratified buildings tend to overheat or overcool based on the temperature at the thermostat, which tends to be lower than the overall heat energy present in the room. The study also showed that energy waste due to stratification was present at ceiling heights ranging from 20 ft. to 40 ft, and higher ceilings caused ...

  7. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    The lower temperatures and large surface area of underfloor heating systems make them ideal heat emitters for air source heat pumps, evenly and effectively radiating the heat energy from the system into rooms within a home. The maximum temperature of the heating surface can vary from 29–35 °C (84–95 °F) depending on the room type.

  8. Seasonal thermal energy storage - Wikipedia

    en.wikipedia.org/wiki/Seasonal_thermal_energy...

    A ground source heat pump is used in winter to extract the warmth from the Thermal Bank to provide space heating via underfloor heating. A high Coefficient of performance is obtained because the heat pump starts with a warm temperature of 25 °C (77 °F) from the thermal store, instead of a cold temperature of 10 °C (50 °F) from the ground. [17]

  9. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    These systems depend on the proper operation of thermostatic air-venting valves located on radiators throughout the heated area. When the system is not in use, these valves are open to the atmosphere, and radiators and pipes contain air. When a heating cycle begins, the boiler produces steam, which expands and displaces the air in the system.