The cooling load temperature difference (CLTD) calculation method, also called the cooling load factor (CLF) or solar cooling load factor (SCL) method, is a method of estimating the cooling load or heating load of a building. It was introduced in the 1979 ASHRAE handbook.
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
The building balance point temperature is the base temperature necessary to calculate heating degree day to anticipate the annual energy demand to heat a building. The balance point temperature is a consequence of building design and function rather than outdoor weather conditions. [2] Internal and external heat gains and losses in a building.
A typical building simulation model has inputs for local weather such as Typical Meteorological Year (TMY) file; building geometry; building envelope characteristics; internal heat gains from lighting, occupants and equipment loads; heating, ventilation, and cooling (HVAC) system specifications; operation schedules and control strategies. [2]
Heating degree day. Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature. The heating requirements for a given building at a specific location are considered to be directly proportional to the number of HDD at that location.
In building design, thermal mass is a property of the matter of a building that requires a flow of heat in order for it to change temperature. In scientific writing the term "heat capacity" is preferred. It is sometimes known as the thermal flywheel effect. [1] The thermal mass of heavy structural elements can be designed to work alongside a ...
The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1][2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.
Coordinates: 36°44′16″N119°47′02″W36.7377°N 119.7838°W. Diagram of air movement in an underfloor air distribution system. Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply ...