enow.com Web Search

  1. Ads

    related to: overhead applied calculator for wall insulation requirements

Search results

  1. Results from the WOW.Com Content Network
  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    R. -value (insulation) The R-value (in K ⋅ m 2/ W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3] R-value is the temperature difference per unit of heat flux needed to sustain one unit of ...

  3. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...

  4. External wall insulation - Wikipedia

    en.wikipedia.org/wiki/External_wall_insulation

    External wall insulation. An external wall insulation system (or EWIS) is a thermally insulated, protective, and decorative exterior cladding procedure involving the use of expanded polystyrene, mineral wool, polyurethane foam or phenolic foam, topped off with a reinforced cement based, mineral or synthetic finish and plaster. [1]

  5. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  6. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    By installing insulation, buildings use less energy for heating and cooling and occupants experience less thermal variability. Retrofitting buildings with further insulation is an important climate change mitigation tactic, [1][2] especially when buildings are heated by oil, natural gas, or coal-based electricity.

  7. Thermal mass - Wikipedia

    en.wikipedia.org/wiki/Thermal_mass

    Thermal mass in this situation is best applied over a large area rather than in large volumes or thicknesses. 7.5–10 cm (3″–4″) is often adequate. Since the most important source of thermal energy is the Sun, the ratio of glazing to thermal mass is an important factor to consider.

  8. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    A typical displacement ventilation system, such as one in an office space, supplies conditioned cold air from an air handling unit (AHU) through a low induction air diffuser. Diffuser types vary by applications. Diffusers can be located against a wall ("wall-mounted"), at the corner of a room ("corner-mounted"), or above the floor but not ...

  9. Thermal insulation - Wikipedia

    en.wikipedia.org/wiki/Thermal_insulation

    Thermal insulation. Thermal insulation is the reduction of heat transfer (i.e., the transfer of thermal energy between objects of differing temperature) between objects in thermal contact or in range of radiative influence. Thermal insulation can be achieved with specially engineered methods or processes, as well as with suitable object shapes ...