Nasogastric intubation is a medical process involving the insertion of a plastic tube (nasogastric tube or NG tube) through the nose, down the esophagus, and down into the stomach. Orogastric intubation is a similar process involving the insertion of a plastic tube ( orogastric tube ) through the mouth. [ 1 ]
For human use, tubes range in size from 2 to 10.5 mm in internal diameter (ID). The size is chosen based on the patient's body size, with the smaller sizes being used for pediatric and neonatal patients. Tubes larger than 6 mm ID usually have an inflatable cuff. Originally made from red rubber, most modern tubes are made from polyvinyl chloride ...
A gastric feeding tube (G-tube or "button") is a tube inserted through a small incision in the abdomen into the stomach and is used for long-term enteral nutrition. One type is the percutaneous endoscopic gastrostomy (PEG) tube which is placed endoscopically.
The Broselow Tape, also called the Broselow pediatric emergency tape, is a color-coded length-based tape measure that is used throughout the world for pediatric emergencies. The Broselow Tape relates a child's height as measured by the tape to their weight to provide medical instructions including medication dosages , the size of the equipment ...
The tracheal tube exchanger is a hollow catheter, 56 to 81 cm (22.0 to 31.9 in) in length, that can be used for removal and replacement of tracheal tubes without the need for laryngoscopy. [22] The Cook Airway Exchange Catheter (CAEC) is another example of this type of catheter; this device has a central lumen (hollow channel) through which ...
The French scale measures the outer diameter of the catheter, not the size of the internal drainage channel (inner diameter). For instance, a two-way catheter of 20 Fr and a three-way catheter of 20 Fr have the same outer diameter, but the three-way catheter has an additional channel for irrigation, reducing the size of its drainage channel.
There are six sizes of the laryngeal tube, ranging from newborn (size 0) to large adult (size 5). The connector of the tube is color-coded for each size. The different sizes are calibrated according to weight or height. [2] The laryngeal tube was licensed for use during cardiopulmonary resuscitation in Japan in 2002, [2] and approved for use in ...
A Miller–Abbott tube is a tube used to treat obstructions in the small intestine through intubation. [1] It was developed in 1934 by William Osler Abbott and Thomas Grier Miller . The device is around 3 metres (9.8 ft) [ 2 ] long and has a distal balloon at one end.