enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  4. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.

  5. Double switching - Wikipedia

    en.wikipedia.org/wiki/Double_switching

    A double-switched relay cannot close inadvertently with the application of the same current. At least two separate faults would be required to allow this relay to close inadvertently. Double switching , double cutting , or double breaking is the practice of using a multipole switch to close or open both the positive and negative sides of a DC ...

  6. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    The neutral wire is connected to the neutral busbar to the left with all the white wires, and the two hot wires are attached to the main breaker. Below the main breaker are the two bus bars carrying the current between the main breaker and the two columns of branch circuit breakers, with each respective circuit's red and black hot wires leading ...

  7. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Two-pole common-trip breakers are common on 120/240-volt systems where 240 volt loads (including major appliances or further distribution boards) span the two live wires. Three-pole common-trip breakers are typically used to supply three-phase power to powerful motors or further distribution boards.

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  9. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.