enow.com Web Search

  1. Ads

    related to: electrical cable testing standards

Search results

  1. Results from the WOW.Com Content Network
  2. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 62230 Electric cables – Spark-test method IEC 62231 Composite station post insulators for substations with AC voltages greater than 1 000 V up to 245 kV IEC 62232 Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

  3. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    DC testing has also been shown to reduce the remaining life of cables with aged polymer insulation. [1] VLF testing of cables is supported in IEC 60502 (up to 35 kV) and in IEEE 400.2 (up to 69 kV). As higher voltage VLF equipment is developed, standards may be adapted to increase the voltage level for application.

  4. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  5. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    A cable terminated according to T568A on one end and T568B on the other is a crossover cable when used with the earlier twisted-pair Ethernet standards that use only two of the pairs because the pairs used happen to be pairs 2 and 3, the same pairs on which T568A and T568B differ. Crossover cables are occasionally needed for 10BASE-T and ...

  6. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    Different test standards apply for consumer electronics, military electrical devices, high-voltage cables, switchgear and other apparatus. [2] Typical hipot equipment leakage current trip limit settings range between 0.1 and 20 mA [3] and are set by the user according to test object characteristics and rate of voltage application. The objective ...

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Wire types for North American wiring practices are defined by standards issued by Underwriters Laboratories, the Canadian Standards Association, the American Society for Testing and Materials, the National Electrical Manufacturers Association, and the Insulated Cable Engineers Association.

  1. Ads

    related to: electrical cable testing standards