Search results

  1. Results from the WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    [1] An air release valve on an elevated section of a large diameter lavender-colored pipe. A working system should not generate further trapped gas. Air may be drawn in if there is a small leak, or dissolved air in make-up water may come out of solution, but this generally indicates a system leak if new water is needing to be added.

  3. Radiator reflector - Wikipedia

    en.wikipedia.org/wiki/Radiator_reflector

    In his 3m cubed test room with a 1 x 0.5 m radiator and walls of average U value 0.44 W/m 2 K, he found that for a radiator temperature of 43 °C the heat flux through the wall behind the radiator reduced from 7.1 to 3.1 W/m 2. Note that the average heat loss in the room was not reduced by such a large percentage as only part of the surface of ...

  4. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.

  5. Radiator (heating) - Wikipedia

    en.wikipedia.org/wiki/Radiator_(heating)

    A radiator is a device that transfers heat to a medium primarily through thermal radiation.In practice, the term radiator is often applied to any number of devices in which a fluid circulates through exposed pipes (often with fins or other means of increasing surface area), notwithstanding that such devices tend to transfer heat mainly by convection and might logically be called convectors.

  6. Insulated pipe - Wikipedia

    en.wikipedia.org/wiki/Insulated_pipe

    Insulated pipes are commonly used for transport of hot water from district heating plants to district heating networks and for distribution of hot water inside district heating networks. Thermal insulation material usually used is polyurethane foam or similar, with a thermal conductivity λ 50 of about 0.024–0.033 W/(m·K

  7. Removable insulation blanket - Wikipedia

    en.wikipedia.org/wiki/Removable_insulation_blanket

    Removable insulation blankets are also known as removable insulation pads, removable insulation covers, and removable insulation jackets. Removable insulation blankets can be installed on many indoor and outdoor components such as boilers, steam traps, pipes, valves, flanges, and more. [2] They are typically used to prevent heat from escaping ...

  8. Trace heating - Wikipedia

    en.wikipedia.org/wiki/Trace_heating

    Hot water service piping can also be traced, so that a circulating system is not needed to provide hot water at outlets. The combination of trace heating and the correct thermal insulation for the operating ambient temperature maintains a thermal balance where the heat output from the trace heating matches the heat loss from the pipe.

  9. Pipe insulation - Wikipedia

    en.wikipedia.org/wiki/Pipe_insulation

    Insulated hot water supply and return hydronic piping on a gas-fired boiler. Since pipework can operate at temperatures far removed from the ambient temperature, and the rate of heat flow from a pipe is related to the temperature differential between the pipe and the surrounding ambient air, heat flow from pipework can be considerable.