Search results

  1. Results from the WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    In a closed heating system though, it has no other means of escape and builds up. An air bubble trapped within a radiator means that no hot water circulates in the upper part and so the heating power of the radiator is reduced. If air is trapped within the boiler this may cause pump cavitation or boiling and overheating within the heat exchanger.

  3. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.

  4. Removable insulation blanket - Wikipedia

    en.wikipedia.org/wiki/Removable_insulation_blanket

    Removable insulation blankets for freeze prevention: used to prevent subfreezing temperatures from affecting an indoor or outdoor component or pipe. Freeze damage can be costly and time consuming to repair, as often the only solution is to let the component thaw. Removable insulation blankets for sound attenuation: used to quiet noisy ...

  5. Radiator (heating) - Wikipedia

    en.wikipedia.org/wiki/Radiator_(heating)

    A hot-water radiator consists of a sealed hollow metal container filled with hot water from a boiler or other heating device by gravity feed, a pump, or natural convection. As it gives out heat, the hot water cools and sinks to the bottom of the radiator and is forced out of a pipe at the other end.

  6. Radiator reflector - Wikipedia

    en.wikipedia.org/wiki/Radiator_reflector

    In his 3m cubed test room with a 1 x 0.5 m radiator and walls of average U value 0.44 W/m 2 K, he found that for a radiator temperature of 43 °C the heat flux through the wall behind the radiator reduced from 7.1 to 3.1 W/m 2. Note that the average heat loss in the room was not reduced by such a large percentage as only part of the surface of ...

  7. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    Hydronic radiant floor heating systems use a boiler or district heating to heat water and a pump to circulate the hot water in plastic pipes installed in a concrete slab. The pipes, embedded in the floor, carry heated water that conducts warmth to the surface of the floor, where it broadcasts heat energy to the room above.

  8. Trace heating - Wikipedia

    en.wikipedia.org/wiki/Trace_heating

    Hot water service piping can also be traced, so that a circulating system is not needed to provide hot water at outlets. The combination of trace heating and the correct thermal insulation for the operating ambient temperature maintains a thermal balance where the heat output from the trace heating matches the heat loss from the pipe.

  9. Insulated pipe - Wikipedia

    en.wikipedia.org/wiki/Insulated_pipe

    Insulated pipes are commonly used for transport of hot water from district heating plants to district heating networks and for distribution of hot water inside district heating networks. Thermal insulation material usually used is polyurethane foam or similar, with a thermal conductivity λ 50 of about 0.024–0.033 W/(m·K