Search results
Results from the WOW.Com Content Network
Tilting-disc inconel check valve Check valve symbol on piping and instrumentation diagrams.The arrow shows the flow direction. Vertical lift check valve. A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction.
A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.
In 1996, NIAflow development began under the name “NIAexpert” as software for sizing and selection of vibrating screens. Its further development began in 2007 as “NIAproject [1] ” which included a mathematical model to simulate a close-to-reality screening process on vibrating screens. It also offered multi-machine calculations and ...
Double beat valve; Double check valve; Duckbill valve; Fill and drain valve: a valve used in space and missile industry which achieves extremely tight leakage, while providing redundant inhibits against external leakage [1] Flapper valve; Flow divider valve: a valve providing a plurality of output flows from a single fluid source [2]
Traditional control valves make it inevitable. As we size a control valve, the K v calculated almost certainly will not match the K v of the nearest appropriate valve. For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more ...
To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity.