A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).
A free concentration [A] ... the detection limit for that species will be lower. ... The minimization can be performed in a spreadsheet application such as EXCEL by ...
Stripping analysis has the following properties: sensitive and reproducible (RSD<5%) method for trace metal ion analysis in aqueous media, 2) concentration limits of detection for many metals are in the low ppb to high ppt range (S/N=3) and this compares favorably with AAS or ICP analysis, field deployable instrumentation that is inexpensive ...
NAA can detect up to 74 elements depending upon the experimental procedure, with minimum detection limits ranging from 0.1 to 1x10 6 ng g −1 depending on element under investigation. Heavier elements have larger nuclei, therefore they have a larger neutron capture cross-section and are more likely to be activated.
The detection limit for electron capture detectors is 5 femtograms per second (fg/s) and the detector commonly exhibits a 10,000-fold linear range. [ citation needed ] This made it possible to detect halogenated compounds such as pesticides and CFCs , even at levels of only one part per trillion ( ppt ), thus revolutionizing our understanding ...
The Gran plot is based on the Nernst equation which can be written as = + {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.
The silver concentration in the test sample is the x-intercept of the plot. The dilution factor is multiplied by this initial concentration to determine the original concentration. Matrix effects occur even with methods such as plasma spectrometry, which have a reputation for being relatively free from interferences. As such, analyst would use ...