enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A hunk of copper is visible that is designed to be easily connected or disconnected from its place between two screws, rated for 600 A (as stamped on it). We also see the thick wires in standard colors (two yellow/green ground and two blue neutral), as well as markings PEN (protected earth and neutral), PE (protective earth) and N (neutral).

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Hot is any line or neutral conductor (wire or otherwise) connected with an electrical system that has electric potential relative to electrical ground or line to neutral. Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1]

  4. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    While the national wiring regulations for buildings of many countries follow the IEC 60364 terminology, in North America (United States and Canada), the term "equipment grounding conductor" refers to equipment grounds and ground wires on branch circuits, and "grounding electrode conductor" is used for conductors bonding an earth/ground rod ...

  5. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Long-distance electromagnetic telegraph systems from 1820 onwards [a] used two or more wires to carry the signal and return currents. It was discovered by German scientist C.A. von Steinheil in 1836–1837, that the ground could be used as the return path to complete the circuit, making the return wire unnecessary. [2]

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The center tap is grounded and one pole is fed to an overhead wire section, while the other wire is used for another section. Split-phase distribution is used on Amtrak's 60 Hz traction power system in the Northeast Corridor between New York and Boston. Two separate wires are run along the track, the contact wire for the locomotive and an ...

  7. Utility pole - Wikipedia

    en.wikipedia.org/wiki/Utility_pole

    A delta system requires only a conductor for each of the three phases. A grounded-wye system requires a fourth conductor, the neutral, whose source is the center of the "Y" and is grounded. However, "spur lines" branching off the main line to provide power to side streets often carry only one or two phase wires, plus the neutral.

  8. NYT ‘Connections’ Hints and Answers Today, Wednesday, January 15

    www.aol.com/nyt-connections-hints-answers-today...

    If you've been having trouble with any of the connections or words in Wednesday's puzzle, you're not alone and these hints should definitely help you out. Plus, I'll reveal the answers further ...

  9. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...