enow.com Web Search

  1. Ads

    related to: calibrating ph meter with buffer tank pump system
    • Our Services

      Comprehensive Calibration Services

      Full service calibration

    • Request Quote

      Get a free quote

      Equipment service quote for free

Search results

  1. Results from the WOW.Com Content Network
  2. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    In-line or in situ pH meters, also called pH analyzers, are used to measure pH continuously in a process, and can stand-alone, or be connected to a higher level information system for process control. [20] pH meters range from simple and inexpensive pen-like devices to complex and expensive laboratory instruments with computer interfaces and ...

  3. Buffer solution - Wikipedia

    en.wikipedia.org/wiki/Buffer_solution

    A buffer solution is a solution where the pH does not change significantly on dilution or if an acid or base is added at constant temperature. [1] Its pH changes very little when a small amount of strong acid or base is added to it. Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical ...

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  5. Phosphate-buffered saline - Wikipedia

    en.wikipedia.org/wiki/Phosphate-buffered_saline

    Phosphate-buffered saline (PBS) is a buffer solution (pH ~ 7.4) commonly used in biological research. It is a water-based salt solution containing disodium hydrogen phosphate, sodium chloride and, in some formulations, potassium chloride and potassium dihydrogen phosphate. The buffer helps to maintain a constant pH.

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Glass electrode - Wikipedia

    en.wikipedia.org/wiki/Glass_electrode

    The bottom of a pH electrode balloons out into a round thin glass bulb. The pH electrode is best thought of as a tube within a tube. The inner tube contains an unchanging 1×10 −7 mol/L HCl solution. Also inside the inner tube is the cathode terminus of the reference probe.

  8. McIlvaine buffer - Wikipedia

    en.wikipedia.org/wiki/McIlvaine_buffer

    McIlvaine buffer is a buffer solution composed of citric acid and disodium hydrogen phosphate, also known as citrate-phosphate buffer. It was introduced in 1921 by the United States agronomist Theodore Clinton McIlvaine (1875–1959) from West Virginia University , and it can be prepared in pH 2.2 to 8 by mixing two stock solutions.

  9. Potassium hydrogen phthalate - Wikipedia

    en.wikipedia.org/wiki/Potassium_hydrogen_phthalate

    The buffering region is dependent upon the pKa, and is typically +/- 1.0 pH units of the pKa. The pKa of KHP is 5.4, so its pH buffering range would be 4.4 to 6.4; however, due to the presence of the second acidic group that bears the potassium ion, the first pKa also contributes to the buffering range well below pH 4.0, which is why KHP is a ...

  1. Ads

    related to: calibrating ph meter with buffer tank pump system