Search results
Results from the WOW.Com Content Network
As an interim resolution, Intel recommends changing the drive controller to AHCI or RAID before installing an operating system. [3] (It may also be necessary to load chipset-specific AHCI or RAID drivers at installation time, for example from a USB flash drive).
The older "Intel Matrix RAID" is supported under Microsoft Windows XP. Linux supports Matrix RAID and Rapid Storage Technology (RST) through device mapper, with dmraid tool, for RAID 0, 1 and 10. And Linux MD RAID, with mdadm tool, for RAID 0, 1, 10, and 5. Set up of the RAID volumes must be done by using the ROM option in the Matrix Storage ...
[4] [5] Linux kernels support AHCI natively since version 2.6.19, and FreeBSD fully supports AHCI since version 8.0. Windows Vista and Windows 7 also natively support AHCI, but their AHCI support (via the msahci service) must be manually enabled via registry editing if controller support was not present during their initial install.
Unlike the network interface controllers for Ethernet, which can be usually be configured and serviced entirely through the common operating system paradigms like ifconfig in Unix, without a need for any third-party tools, each manufacturer of each RAID controller usually provides their own proprietary software tooling for each operating system ...
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
RAID 5E, RAID 5EE, and RAID 6E (with the added E standing for Enhanced) generally refer to variants of RAID 5 or 6 with an integrated hot-spare drive, where the spare drive is an active part of the block rotation scheme. This spreads I/O across all drives, including the spare, thus reducing the load on each drive, increasing performance.
Pages in category "Game engines for Linux" The following 51 pages are in this category, out of 51 total. This list may not reflect recent changes. 0–9. 4A Engine; B.
A flawed RAID 5/6 also exists, but can result in data loss.) [10] For RAID 1, the devices must have complementary sizes. For example, a filesystem spanning two 500 GB devices and one 1 TB device could provide RAID1 for all data, while a filesystem spanning a 1 TB device and a single 500 GB device could only provide RAID1 for 500 GB of data.