The microscope setup is based on an inverted microscope design. [ 2 ] [ 3 ] [ 4 ] An automated stage is used to record larger areas by mosaicing a series of single adjacent frames. The LED light is focused using a ball lens with a short focal length onto the sample surface in an oblique-angle cis-illumination scheme since standard microscopy ...
As can be seen in Figure 1, these detectors have a light source, a dispersion element that is a diffraction grating or prism, a flow cell, to where the sample arrives directly from the chromatographic column, an optical bench of lenses and mirrors, and a diode that receives the light coming from the optical system and translates it into a ...
Memorial in Jena, Germany to Ernst Karl Abbe, who approximated the diffraction limit of a microscope as = , where d is the resolvable feature size, λ is the wavelength of light, n is the index of refraction of the medium being imaged in, and θ (depicted as α in the inscription) is the half-angle subtended by the optical objective lens (representing the numerical aperture).
UV–visible spectroscopy of microscopic samples is done by integrating an optical microscope with UV–visible optics, white light sources, a monochromator, and a sensitive detector such as a charge-coupled device (CCD) or photomultiplier tube (PMT). As only a single optical path is available, these are single beam instruments.
Excitation source: a device that produces either a broad-wavelength source like UV light, or a narrow wavelength source like a laser. Light display optics: the mechanism of which light illuminates the sample. This is typically done through direct illumination of the sample. Light assortment optics: the collection method of the light itself.
Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.
A sample of herring sperm stained with SYBR green in a cuvette illuminated by blue light in an epifluorescence microscope. The SYBR green in the sample binds to the herring sperm DNA and, once bound, fluoresces giving off green light when illuminated by blue light. In order for a sample to be suitable for fluorescence microscopy it must be ...
Quartz or mirror-based optics can be used for studying samples from the ultraviolet (UV), down to 200 nm, to the near infrared (NIR) up to 2100 nm. Samples that emit electromagnetic radiation via fluorescence, phosphorescence or photoluminescence when exposed to light, can be quantitatively investigated using a variety of excitation and barrier ...