enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cardiology diagnostic tests and procedures - Wikipedia

    en.wikipedia.org/wiki/Cardiology_diagnostic...

    Electrocardiography (ECG/EKG in German vernacular. Elektrokardiogram) monitors electrical activity of the heart, primarily as recorded from the skin surface. A 12 lead recording, recording the electrical activity in three planes, anterior, posterior, and lateral is the most commonly used form.

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    A standard 12-lead ECG report (an electrocardiograph) shows a 2.5 second tracing of each of the twelve leads. The tracings are most commonly arranged in a grid of four columns and three rows. The first column is the limb leads (I, II, and III), the second column is the augmented limb leads (aVR, aVL, and aVF), and the last two columns are the ...

  4. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    The use of additional ECG leads like right-sided leads V3R and V4R and posterior leads V7, V8, and V9 may improve sensitivity for right ventricular and posterior myocardial infarction. In spite of these limitations, the 12 lead ECG stands at the center of risk stratification for the patient with suspected acute myocardial infarction.

  5. Diagnosis of myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Diagnosis_of_myocardial...

    The standard 12 lead ECG does not directly examine the right ventricle, and is relatively poor at examining the posterior basal and lateral walls of the left ventricle. In particular, acute myocardial infarction in the distribution of the circumflex artery is likely to produce a nondiagnostic ECG. [ 10 ]

  6. Cardiac monitoring - Wikipedia

    en.wikipedia.org/wiki/Cardiac_monitoring

    Cardiac monitoring generally refers to continuous or intermittent monitoring of heart activity to assess a patient's condition relative to their cardiac rhythm.Cardiac monitoring is usually carried out using electrocardiography, which is a noninvasive process that records the heart's electrical activity and displays it in an electrocardiogram. [1]

  7. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    In humans, for an ECG to be described as showing a sinus rhythm, the shape of the P wave in each of the 12 standard ECG leads should be consistent with a "typical P vector" of +50° to +80°. [2] This means that the P wave should be: always positive in lead I, lead II, and aVF; always negative in lead aVR

  8. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    This refers to the appearance of leads I and II. If the QRS complex is negative in lead I and positive in lead II, the QRS complexes appear to be "reaching" to touch each other. This signifies right axis deviation. Conversely, if the QRS complex is positive in lead I and negative in lead II the leads have the appearance of "leaving" each other.

  9. ST elevation - Wikipedia

    en.wikipedia.org/wiki/ST_elevation

    An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...