Equivalent mesh sizes from 5 μm to 25.4 mm also exist. [1] [2] [3] Available sieve sizes are usually regulated by standards. Those in common use are ISO 565:1990 and ISO 3310-1:2000 (international), [4] EN 933-1(European) [5] and ASTM E11:01 (US). EN standards are available with national 'badging'; so they appear as BS EN, FR EN, DE EN, etc.
A sieve analysis (or gradation test) is a practice or procedure used in geology, civil engineering, [1] and chemical engineering [2] to assess the particle size distribution (also called gradation) of a granular material by allowing the material to pass through a series of sieves of progressively smaller mesh size and weighing the amount of material that is stopped by each sieve as a fraction ...
> 50% of coarse fraction retained on No.4 (4.75 mm) sieve clean gravel <5% smaller than No.200 Sieve GW well-graded gravel, fine to coarse gravel GP poorly graded gravel gravel with >12% fines GM silty gravel GC clayey gravel sand ≥ 50% of coarse fraction passes No.4 (4.75 mm) sieve clean sand SW well-graded sand, fine to coarse sand SP
Soil gradation is determined by analyzing the results of a sieve analysis or a hydrometer analysis. [4] [5] In a sieve analysis, a coarse-grained soil sample is shaken through a series of woven-wire square-mesh sieves. Each sieve has successively smaller openings so particles larger than the size of each sieve are retained on the sieve.
A variety of sieve sizes are available. The boundary between sand and silt is arbitrary. According to the Unified Soil Classification System, a #4 sieve (4 openings per inch) having 4.75 mm opening size separates sand from gravel and a #200 sieve with an 0.075 mm opening separates sand from silt and clay. According to the British standard, 0. ...
Test methodology and equipment is defined in the ASTM International publications ASTM C131 for particle sizes smaller than 37 mm (1.5 inches) and ASTM C535 for sizes larger than 19 mm (3/4 of an inch); the overlapping range of 19 to 37 mm can be tested by either of two standards. [1] [2]
Nmagedman> The "Sieve size conversion chart" has columns labeled BSS, Tyler, and US. Tyler is described in the article, but BSS and US are not. Could someone please describe those systems? Further, the article describes FEPA scales, but they are not included in the chart. Would someone please add them? Thanks! 17:28, 11 April 2007 (UTC)
PSD is usually defined by the method by which it is determined. The most easily understood method of determination is sieve analysis, where powder is separated on sieves of different sizes. Thus, the PSD is defined in terms of discrete size ranges: e.g. "% of sample between 45 μm and 53 μm", when sieves of these sizes are used.