Warman centrifugal pump in a coal preparation plant application A pair of centrifugal pumps for circulating hot water within a hydronic heating system. Centrifugal pumps are used to transport fluids by the conversion of rotational kinetic energy to the hydrodynamic energy of the fluid flow. The rotational energy typically comes from an engine ...
While centrifugal pumps impart momentum to the fluid by motion of blades, positive displacement pumps transfer fluid by variation in the size of the pump’s chamber. Centrifugal pumps can be of rotor or propeller types, whereas positive displacement pumps may be gear-based, piston-based, diaphragm-based, etc. As a general rule, centrifugal ...
Circulator pumps as used in hydronic systems are usually electrically powered centrifugal pumps. As used in homes, they are often small, sealed, and rated at a fraction of a horsepower , but in commercial applications they range in size up to many horsepower and the electric motor is usually separated from the pump body by some form of ...
A chopper pump is a centrifugal pump which is equipped with a cutting system to facilitate chopping or maceration of solids that are present in the pumped liquid. The main advantage of this type of pump is that it prevents clogging of the pump itself and of the adjacent piping, as all the solids and stringy materials are macerated by the ...
API Standard 682, titled "Pumps - Shaft Sealing Systems for Centrifugal and Rotary Pumps," is the American Petroleum Institute standard for end-face mechanical seals. [1] The purpose of API 682 is to assist in the selection and operation of end face mechanical seals in centrifugal pumps. It is based on the combined knowledge and experience of ...
Pump and volute casing. A volute is a curved funnel that increases in area as it approaches the discharge port. [1] The volute of a centrifugal pump is the casing that receives the fluid being pumped by the impeller, maintaining the velocity of the fluid through to the diffuser. As liquid exits the impeller it has high kinetic energy and the ...
Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...
If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.