Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass.Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmful effects), and radiology (potential beneficial effects, for example in cancer treatment).
That model calculates an effective radiation dose, measured in units of rem, which is more representative of the stochastic risk than the absorbed dose in rad. In most power plant scenarios, where the radiation environment is dominated by X-or gamma rays applied uniformly to the whole body, 1 rad of absorbed dose gives 1 rem of effective dose. [5]
The International Committee for Weights and Measures states: "In order to avoid any risk of confusion between the absorbed dose D and the dose equivalent H, the special names for the respective units should be used, that is, the name gray should be used instead of joules per kilogram for the unit of absorbed dose D and the name sievert instead ...
In 1953 the International Commission on Radiation Units and Measurements (ICRU) recommended the rad, equal to 100 erg/g, as the unit of measure of the new radiation quantity absorbed dose. The rad was expressed in coherent cgs units. [5] In 1975 the unit gray was named as the SI unit of absorbed dose. One gray is equal to 1 J/kg (i.e. 100 rad).
The fundamental quantity is the absorbed dose (D), which is defined as the mean energy imparted [by ionising radiation] (dE) per unit mass (dm) of material (D = dE/dm) [8] The SI unit of absorbed dose is the gray (Gy) defined as one joule per kilogram. Absorbed dose, as a point measurement, is suitable for describing localised (i.e. partial ...
The absorbed dose, measured in rad, is a better indicator of ARS. [3]: 592–593 A rem is a large dose of radiation, so the millirem (mrem), which is one thousandth of a rem, is often used for the dosages commonly encountered, such as the amount of radiation received from medical x-rays and background sources.
Since different radiation types have different biological effects for the same deposited energy, a corrective radiation weighting factor W R, which is dependent on the radiation type and on the target tissue, is applied to convert the absorbed dose measured in the unit gray to determine the equivalent dose. The result is given the unit sievert.
The SI unit for effective dose is the sievert (Sv) which represents a 5.5% chance of developing cancer. [4] The effective dose is not intended as a measure of deterministic health effects, which is the severity of acute tissue damage that is certain to happen, that is measured by the quantity absorbed dose. [5]