enow.com Web Search

  1. Ad

    related to: accurate triangle drawer test for concrete slab

Search results

  1. Results from the WOW.Com Content Network
  2. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...

  3. Alkali–silica reaction - Wikipedia

    en.wikipedia.org/wiki/Alkali–silica_reaction

    ASTM C1293: "Test Method for Concrete Aggregates by Determination of Length Change of Concrete Due to Alkali-Silica Reaction". It is a long-term confirmation test (1 or 2 years) at 38 °C in a water-saturated moist atmosphere (inside a thermostated oven) with concrete prisms containing the aggregates to be characterised mixed with a high-alkali ...

  4. Three-point flexural test - Wikipedia

    en.wikipedia.org/wiki/Three-point_flexural_test

    The three-point bending flexural test provides values for the modulus of elasticity in bending, flexural stress, flexural strain and the flexural stress–strain response of the material. This test is performed on a universal testing machine (tensile testing machine or tensile tester) with a three-point or four-point bend fixture.

  5. Thermal integrity profiling - Wikipedia

    en.wikipedia.org/wiki/Thermal_integrity_profiling

    Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.

  6. Falling weight deflectometer - Wikipedia

    en.wikipedia.org/wiki/Falling_weight_deflectometer

    FWD data is most often used to calculate stiffness-related parameters of a pavement structure. The process of calculating the elastic moduli of individual layers in a multi-layer system (e.g. asphalt concrete on top of a base course on top of the subgrade) based on surface deflections is known as "backcalculation", as there is no closed-form solution.

  7. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  8. Electrical resistivity measurement of concrete - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivity...

    Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration. ASTM Standard C1202-10. Standard Test Method for Surface Resistivity of Concrete's Ability to Resist Chloride Ion Penetration. Washington, D.C., USA: American Association of State Highway and Transportation Officials. 2011. AASHTO TP 95.

  9. Concrete moisture meter - Wikipedia

    en.wikipedia.org/wiki/Concrete_moisture_meter

    Concrete moisture meters are designed to detect moisture to a depth of 1 inch (25 mm) of a concrete slab in order to avoid the rebar reinforcement below the surface. [1] They are designed to be used as a relative test. [2] The meters are used to "'Spot check' the top surface at one particular location on the slab."

  1. Ad

    related to: accurate triangle drawer test for concrete slab