Search results
Results from the WOW.Com Content Network
In precipitation reactions, the equivalence factor measures the number of ions which will precipitate in a given reaction. Here, 1 / f eq is an integer value. Normal concentration of an ionic solution is also related to conductivity (electrolytic) through the use of equivalent conductivity.
Both equivalence points are visible. A titration curve is a curve in graph the x-coordinate of which represents the volume of titrant added since the beginning of the titration, and the y-coordinate of which represents the concentration of the analyte at the corresponding stage of the titration (in an acid–base titration, the y-coordinate ...
The equivalence point, or stoichiometric point, of a chemical reaction is the point at which chemically equivalent quantities of reactants have been mixed. For an acid-base reaction the equivalence point is where the moles of acid and the moles of base would neutralize each other according to the chemical reaction.
Overshooting the equivalence point can occur due to various factors, such as errors in burette readings, imperfect reaction stoichiometry, or issues with endpoint detection. [14] The consequences of overshot titrations can affect the accuracy of the analytical results, particularly in quantitative analysis.
A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...
The end point is detected most commonly by a bipotentiometric titration method. A second pair of Pt electrodes is immersed in the anode solution. The detector circuit maintains a constant current between the two detector electrodes during titration. Prior to the equivalence point, the solution contains I − but little I 2.
A related term was the equivalence factor, one gram divided by equivalent weight, which was the numerical factor by which the mass of precipitate had to be multiplied ...
V eq is the volume of titrant (ml) consumed by the crude oil sample and 1 ml of spiking solution at the equivalent point, b eq is the volume of titrant (ml) consumed by 1 ml of spiking solution at the equivalent point, 56.1 g/mol is the molecular weight of KOH, W oil is the mass of the sample in grams. The normality (N) of titrant is calculated as: