enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    Diagram of a RAID 0 setup. RAID 0 (also known as a stripe set or striped volume) splits ("stripes") data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Since RAID 0 provides no fault tolerance or redundancy, the failure of one drive will cause the entire array to fail, due to data being striped ...

  3. Error recovery control - Wikipedia

    en.wikipedia.org/wiki/Error_recovery_control

    The result is increased reliability in a RAID array. In a stand-alone configuration TLER should be disabled. As the drive is not redundant, reporting segments as failed will only increase manual intervention. Without a hardware RAID controller or a software RAID implementation to drop the disk, normal (no TLER) recovery ability is most stable.

  4. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.

  5. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.

  6. Data striping - Wikipedia

    en.wikipedia.org/wiki/Data_striping

    In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy , if one member drive fails the data can be restored using the other drives in the array.

  7. Erasure code - Wikipedia

    en.wikipedia.org/wiki/Erasure_code

    RAID; Erasure Coding; While technically RAID can be seen as a kind of erasure code, [5] "RAID" is generally applied to an array attached to a single host computer (which is a single point of failure), while "erasure coding" generally implies multiple hosts, [3] sometimes called a Redundant Array of Inexpensive Servers (RAIS). The erasure code ...

  8. Error-tolerant design - Wikipedia

    en.wikipedia.org/wiki/Error-tolerant_design

    An error-tolerant design (or human-error-tolerant design [1]) is one that does not unduly penalize user or human errors. It is the human equivalent of fault tolerant design that allows equipment to continue functioning in the presence of hardware faults, such as a "limp-in" mode for an automobile electronics unit that would be employed if ...

  9. Parity drive - Wikipedia

    en.wikipedia.org/wiki/Parity_Drive

    A parity drive is a hard drive used in a RAID array to provide fault tolerance. For example, RAID 3 uses a parity drive to create a system that is both fault tolerant and, because of data striping, fast. [1] Basically, a single data bit is added to the end of a data block to ensure the number of bits in the message is either odd or even. [2]