Ad
related to: nist calibration thermometer manual instructions free
Search results
Results from the WOW.Com Content Network
There are often small differences between measurements calibrated per ITS-90 and thermodynamic temperature.For instance, precise measurements show that the boiling point of VSMOW water under one standard atmosphere of pressure is actually 373.1339 K (99.9839 °C) when adhering strictly to the two-point definition of thermodynamic temperature.
A maximum minimum thermometer, also known as Six's thermometer, is a thermometer which registers the maximum and minimum temperatures reached over a period of time, typically 24 hours. The original design contains mercury, but solely as a way to indicate the position of a column of alcohol whose expansion indicates the temperature; it is not a ...
NIST had an operating budget for fiscal year 2007 (October 1, 2006 – September 30, 2007) of about $843.3 million. NIST's 2009 budget was $992 million, and it also received $610 million as part of the American Recovery and Reinvestment Act. [18] NIST employs about 2,900 scientists, engineers, technicians, and support and administrative personnel.
However, a common temperature and pressure in use by NIST for thermodynamic experiments is 298.15 K (25 °C, 77 °F) and 1 bar (14.5038 psi, 100 kPa). [4] [5] NIST also uses 15 °C (288.15 K, 59 °F) for the temperature compensation of refined petroleum products, despite noting that these two values are not exactly consistent with each other.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
A thermometer has two important elements: (1) a temperature sensor (e.g. the bulb of a mercury-in-glass thermometer or the pyrometric sensor in an infrared thermometer) in which some change occurs with a change in temperature; and (2) some means of converting this change into a numerical value (e.g. the visible scale that is marked on a mercury ...
ASTM Subcommittee E20.02 on Radiation Thermometry is a subcommittee of the ASTM Committee E20 on Temperature Measurement, a committee of ASTM International.The subcommittee is responsible for standards relating to radiation or infrared (IR) temperature measurement.
Six's maximum and minimum thermometer is a registering thermometer that can record the maximum and minimum temperatures reached over a period of time, for example 24 hours. It is used to record the extremes of temperature at a location, for instance in meteorology and horticulture .
Ad
related to: nist calibration thermometer manual instructions free