  2. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A hunk of copper is visible that is designed to be easily connected or disconnected from its place between two screws, rated for 600 A (as stamped on it). We also see the thick wires in standard colors (two yellow/green ground and two blue neutral), as well as markings PEN (protected earth and neutral), PE (protective earth) and N (neutral).

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Hot is any line or neutral conductor (wire or otherwise) connected with an electrical system that has electric potential relative to electrical ground or line to neutral. Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1]

  4. Camlock (electrical) - Wikipedia

    en.wikipedia.org/wiki/Camlock_(electrical)

    The National Electric Code (NEC) only specifies colors for ground and neutral: Green for the equipment grounding (safety) conductor (NEC Article 250.119), and white or grey for the neutral (grounded) conductor (NEC Article 200.6). These colors may not be used for any other purpose, nor may their purpose use a different color.

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Modern non-metallic sheathed cables, such as (US and Canadian) Types NMB and NMC, consist of two to four wires covered with thermoplastic insulation, plus a wire for Protective Earthing/Grounding (bonding), surrounded by a flexible plastic jacket. In North America and the UK this conductor is usually bare wire but in the UK it is required that ...

  6. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    Per UL Standard ANSI/UL 498, a receptacle (any color) with an orange triangle, is an isolated ground (IG) device, where the grounding pin of the receptacle is connected to ground independently of the frame of the receptacle and wiring outlet box. This is also a requirement of the National Electrical Code (NFPA 70), Article 406.

  7. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    In the United States it is not usually used for three phase power but for the high leg delta wiring of split-phase electric power (unknown in Europe). This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase.

  8. Watch 16-Year-Old Gout Gout — Considered the Next Usain Bolt ...

    www.aol.com/watch-16-old-gout-gout-201619345.html

    Meet Gout Gout, the 16-year-old Australian sprinter who recorded the fourth-fastest time by an Australian in the 100-meter race on Friday, Dec. 6. Gout, largely touted as the next Usain Bolt ...

  9. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    While the national wiring regulations for buildings of many countries follow the IEC 60364 terminology, in North America (United States and Canada), the term "equipment grounding conductor" refers to equipment grounds and ground wires on branch circuits, and "grounding electrode conductor" is used for conductors bonding an earth/ground rod ...