enow.com Web Search

  1. Ads

    related to: how to make mass spectrometer full

Search results

  1. Results from the WOW.Com Content Network
  2. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.

  3. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.

  4. Mass spectrum - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrum

    A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...

  5. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    A mass spectrometer is typically utilized in one of two ways: full scan or selective ion monitoring (SIM). The typical GC–MS instrument is capable of performing both functions either individually or concomitantly, depending on the setup of the particular instrument.

  6. Quadrupole mass analyzer - Wikipedia

    en.wikipedia.org/wiki/Quadrupole_mass_analyzer

    In a quadrupole mass spectrometer (QMS) the quadrupole is the mass analyzer – the component of the instrument responsible for selecting sample ions based on their mass-to-charge ratio (m/z). Ions are separated in a quadrupole based on the stability of their trajectories in the oscillating electric fields that are applied to the rods.

  7. Liquid chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Liquid_chromatography...

    Mass spectrometry (MS) is an analytical technique that measures the mass-to-charge ratio (m/z) of charged particles (ions). Although there are many different kinds of mass spectrometers, all of them make use of electric or magnetic fields to manipulate the motion of ions produced from an analyte of interest and determine their m/z. [18]

  8. Mass chromatogram - Wikipedia

    en.wikipedia.org/wiki/Mass_chromatogram

    A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.

  9. Ion trap - Wikipedia

    en.wikipedia.org/wiki/Ion_trap

    A linear ion trap component of a mass spectrometer. An ion trap mass spectrometer may incorporate a Penning trap (Fourier-transform ion cyclotron resonance), [12] Paul trap [13] or the Kingdon trap. [14] The Orbitrap, introduced in 2005, is based on the Kingdon trap. [15] Other types of mass spectrometers may also use a linear quadrupole ion ...

  1. Ads

    related to: how to make mass spectrometer full