LVL is commonly manufactured in North America by companies that also manufacture I-joists. LVL is manufactured to sizes compatible with the depth of I-joist framing members for use as beams and headers. Additionally, some manufacturers further cut LVL into sizes for use as chord-members on I-joists.
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...
The LH- and DLH-Series have been designed for the purpose of extending the use of joists to spans and loads in excess of those covered by Open Web Steel Joists, K-Series. LH-Series Joists have been standardized in depths from 18 inches (460 mm) through 48 inches (1,200 mm), for spans through 96 feet (29,000 mm).
Depths can range from 9 + 1 ⁄ 4 to 24 inches (230–610 mm) and reach up to 80 feet (24 m) in length, although 40 to 42 feet (12–13 m) is more common. The intended use for an I-joist is for floor and roof joists, wall studs, and roof rafters in both residential and commercial construction. [1]
The beams are continuously formed, so the length of the beam is limited only to the maximum length that can be handled and transported. Typical widths are 3 + 1 ⁄ 2, 5 + 1 ⁄ 4 or 7 inches (89, 133 or 178 mm); typical depths are 9 + 1 ⁄ 2, 11 + 7 ⁄ 8, 14, 16 and 18 inches (240, 300, 360, 410 and 460 mm). Typically the beams are made to a ...
Wall framing in house construction includes the vertical and horizontal members of exterior walls and interior partitions, both of bearing walls and non-bearing walls. . These stick members, referred to as studs, wall plates and lintels (sometimes called headers), serve as a nailing base for all covering material and support the upper floor platforms, which provide the lateral strength along a
[5] [3] As a rule of thumb, the depth should be 1 ⁄ 24 of the span. [5] The width of the ribs is typically 130 mm (5 in) to 150 mm (6 in), and ribs usually have steel rod reinforcements. [5] The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3]
A Lally column is a round or square thin-walled structural steel column filled with concrete, [1] and oriented vertically to provide support to beams or timbers stretching over long spans. Lally columns are an engineered component and as such must be installed exactly as the design engineer specified.