With radiant systems, thermal comfort is achieved at warmer interior temp than all-air systems for cooling scenario, and at lower temperature than all-air systems for heating scenario. [21] Thus, radiant systems can helps to achieve energy savings in building operation while maintaining the wished comfort level.
Under floor radiant systems are evaluated for sustainability through the principles of efficiency, entropy, exergy [33] and efficacy. When combined with high-performance buildings, underfloor systems operate with low temperatures in heating and high temperatures in cooling [34] in the ranges found typically in geothermal [35] and solar thermal ...
radiant floor A type of radiant heating system where the building floor contains channels or tubes through which hot fluids such as air or water are circulated. The whole floor is evenly heated. Thus, the room is heated from the bottom up. Radiant floor heating eliminates the draft and dust problems associated with forced air heating systems ...
The mere presence of the raised floor reduces the ability of the slab to store heat, thereby producing for the system with a raised floor higher peak cooling loads compared to the system without a raised floor. In the OH system, particularly in perimeter zones, part of the incoming solar heat gain is stored in the floor slab during the day ...
Compared to other sensible cooling systems, radiant ceiling cooling panels are the best parallel system choice for use with the DOAS. Because the DOAS only accommodates the space ventilation and latent loads, it provides an opportunity to reduce the required floor-to-floor height by reducing the size of the duct system and the required fan ...
A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.
In underfloor heating, tubing is placed on the floor throughout the room and later covered with a concrete layer during construction. Also known as "radiant heat", underfloor heating uses a network of pipes, tubing or heating cables, buried in or attached beneath a floor to allow heat to rise into the room.
The three basic types of radiant cooling are direct, indirect, and fluorescent: Direct radiant cooling - In a building designed to optimize direct radiation cooling, the building roof acts as a heat sink to absorb the daily internal loads. The roof acts as the best heat sink because it is the greatest surface exposed to the night sky.