Search results
Results from the WOW.Com Content Network
These have been added to, creating the 15 rules for 12-lead (and 15- or 18-lead) interpretation. [85] Rule 1: All waves in aVR are negative. Rule 2: The ST segment (J point) starts on the isoelectric line (except in V1 & V2 where it may be elevated by not greater than 1 mm). Rule 3: The PR interval should be 0.12–0.2 seconds long.
Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...
A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG. In order to create the Lewis Lead, the right arm electrode is moved to the manubrium adjacent to the sternum ...
A second electrode acts as the other half of the cell. This second electrode must have a known potential to gauge the potential of the working electrode from; furthermore it must balance the charge added or removed by the working electrode. While this is a viable setup, it has a number of shortcomings.
Chronoamperometry is typically carried out in unstirred solution and at the fixed electrode, i.e., under experimental conditions avoiding convection as the mass transfer to the electrode. On the other hand, voltammetry is a subclass of amperometry, in which the current is measured by varying the potential applied to the electrode.
The chemical reactions in the cell involve the electrolyte, electrodes, and/or an external substance (fuel cells may use hydrogen gas as a reactant). In a full electrochemical cell, species from one half-cell lose electrons to their electrode while species from the other half-cell gain electrons from their electrode.
To avoid possible ambiguities, the electrode potential thus defined can also be referred to as Gibbs–Stockholm electrode potential. In both conventions, the standard hydrogen electrode is defined to have a potential of 0 V. Both conventions also agree on the sign of E for a half-cell reaction when it is written as a reduction.
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .