  2. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Sometimes the fittings are considered sufficiently conductive to bond (electrically unite) the metal conduit to a metal junction box (thus sharing the box's ground connection); other times, grounding bushings are used which have bonding jumpers from the bushing to a grounding screw on the box. [10]

  3. Bushing (electrical) - Wikipedia

    en.wikipedia.org/wiki/Bushing_(electrical)

    In electric power, a bushing is a hollow electrical insulator that allows an electrical conductor to pass safely through a conducting barrier such as the case of a transformer or circuit breaker without making electrical contact with it. Bushings are typically made from porcelain, though other insulating materials are also used.

  4. Pothead - Wikipedia

    en.wikipedia.org/wiki/Pothead

    Multiple bushing insulators project from the plastic body, each ending at an electrical terminal. Each overhead wire is connected to a bushing terminal from which the current passes through a rod down the center of the bushing to the interior of the housing, where it is connected to a wire from the conduit.

  5. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    [2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground.

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Rigid may be required for certain areas and additionally, vapor-lock fittings may be required in areas where a fire or explosion hazard is present (such as gas stations, chemical factories, grain silos, etc.) PVC can be used where wire is run underground or where concrete will be poured. A duct bank is usually made of multiple PVC conduits ...

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A ground fault circuit interrupter (GFCI) is required for all receptacles in wet locations defined in the Code. The NEC also has rules about how many circuits and receptacles should be placed in a given residential dwelling, and how far apart they can be in a given type of room, based upon the typical cord length of small appliances.

  8. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.

  9. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    A double-tapped bushing, commonly shortened to bushing, is a fitting which serves as a reducer. It is a sleeve similar to a close nipple, but is threaded on both its inner and outer circumferences. Like a reducer, a double-tapped bushing has two threads of different sizes.