Search results
Results from the WOW.Com Content Network
The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.
The wound usually appears red and can be accompanied by drainage. Clinicians delay re-opening the wound unless it is necessary due to the potential of other complications. If the surgical wound worsens, or if a rupture of the digestive system is suspected the decision may be to investigate the source of the drainage or infection. [2] [3]
Fistulectomy is a surgical procedure where a surgeon completely removes a fistula, an abnormal tract (i.e. tube) that connects two hollow spaces of the body. [1] [2] In comparison to other procedural options of treating fistulae such as fistulotomies, where a fistula is cut open (i.e. unroofed) but not completely removed, and seton placement, where a rubber band seton is passed through the ...
Healthcare Common Procedure Coding System (including Current Procedural Terminology) (for outpatient use; used in United States) ICD-10 Procedure Coding System (ICD-10-PCS) (for inpatient use; used in United States) ICD-9-CM Volume 3 (subset of ICD-9-CM) (formerly used in United States prior to the introduction of the ICD-10-PCS)
Wound dehiscence following an inguinal hernia repair. Wound dehiscence is a surgical complication in which a wound ruptures along a surgical incision . Risk factors include age, collagen disorder such as Ehlers–Danlos syndrome , diabetes , obesity , poor knotting or grabbing of stitches , and trauma to the wound after surgery.
The wound can be allowed to close by secondary intention. Alternatively, if the infection is cleared and healthy granulation tissue is evident at the base of the wound, the edges of the incision may be reapproximated, such as by using butterfly stitches , staples or sutures .
A Jackson-Pratt drain (also called a JP drain) is a closed-suction medical device that is commonly used as a post-operative drain for collecting bodily fluids from surgical sites. The device consists of an internal drain connected to a grenade-shaped bulb or circular cylinder via plastic tubing. [1]
Jenkin's rule was the first research result in this area, showing that the then-typical use of a suture-length to wound-length ratio of 2:1 increased the risk of a burst wound, and suggesting a SL:WL ratio of 4:1 or more in abdominal wounds. [19] [20] A later study suggested 6:1 as the optimal ratio in abdominal closure. [21]