Search results
Results from the WOW.Com Content Network
The term is considered by many safety professionals to be the same as the lower explosive level (LEL). At a concentration in air lower than the LFL, gas mixtures are "too lean" to burn. Methane gas has an LFL of 4.4%. [1] If the atmosphere has less than 4.4% methane, an explosion cannot occur even if a source of ignition is present.
The limiting oxygen concentration is shown in the lower right of the diagram. The limiting oxygen concentration (LOC), [1] also known as the minimum oxygen concentration (MOC), [2] is defined as the limiting concentration of oxygen below which combustion is not possible, independent of the concentration of fuel. It is expressed in units of ...
Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line. The upper and lower flammability limits of methane in air are located on this line, as shown (labelled UEL and LEL, respectively). The stoichiometric combustion of methane is: CH 4 + 2O 2 → CO 2 + 2H ...
Additionally, oxygen must be present. [7] The flammability limits of gases are expressed in proportions to the other gases present. [citation needed] For example, for methane, research by Akifumi Takahashi et. al. shows limits between 4.4% for the lower explosive limit and the upper explosive limit at 16.3%. [8]
The lower flammability limit (LFL), [1] usually expressed in volume per cent, is the lower end of the concentration range over which a flammable mixture of gas or vapour in air can be ignited at a given temperature and pressure. The flammability range is delineated by the upper and lower flammability limits. Outside this range of air/vapor ...
The Bay Area Air Quality Management District has fined Berkeley after finding explosive levels of methane leaking from at least two cracked gas collection wells in the park. Both have since been ...
The concentration of methane at which asphyxiation risk becomes significant is much higher than the 5–15% concentration in a flammable or explosive mixture. Methane off-gas can penetrate the interiors of buildings near landfills and expose occupants to significant levels of methane. Some buildings have specially engineered recovery systems ...
Whereas the natural units of measurement for an Infrared point sensor are parts-per-million (ppm) or the percentage of the lower flammable limit (%LFL), the natural units of measurement for an open path detector are ppm.metres (ppm.m) or LFL.metres (LFL.m).