enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Schuller's view - Wikipedia

    en.wikipedia.org/wiki/Schuller's_view

    The radiograph for each mastoid is taken separately. Schuller's view serves as an alternate view to the Law projection which uses a 15° angle of patient's face toward the image receptor and a 15° caudal angulation of the computed radiography (CR) to achieve the same result, a lateral mastoid air cells view without overlap of the opposite side.

  3. Chest radiograph - Wikipedia

    en.wikipedia.org/wiki/Chest_radiograph

    A radiation source is positioned behind the patient at a standard distance (most often 6 feet, 1,8m), and the x-ray beam is fired toward the patient. In anteroposterior (AP) views, the positions of the x-ray source and detector are reversed: the x-ray beam enters through the anterior aspect and exits through the posterior aspect of the chest.

  4. Radiation therapy - Wikipedia

    en.wikipedia.org/wiki/Radiation_therapy

    The patient receives small skin marks to guide the placement of treatment fields. [10] Patient positioning is crucial at this stage as the patient will have to be placed in an identical position during each treatment. Many patient positioning devices have been developed for this purpose, including masks and cushions which can be molded to the ...

  5. Waters' view - Wikipedia

    en.wikipedia.org/wiki/Waters'_view

    An x-ray beam is angled at 45° to the orbitomeatal line. The rays pass from behind the head and are perpendicular to the radiographic plate. Another variation of the waters places the orbitomeatal line at a 37° angle to the image receptor. It is named after the American radiologist Charles Alexander Waters.

  6. Rotational angiography - Wikipedia

    en.wikipedia.org/wiki/Rotational_angiography

    Rotational angiography is a medical imaging technique based on x-ray, that allows to acquire CT-like 3D volumes during hybrid surgery or during a catheter intervention using a fixed C-arm. The fixed C-arm thereby rotates around the patient and acquires a series of x-ray images that are then reconstructed through software algorithms into a 3D ...

  7. EOS (medical imaging) - Wikipedia

    en.wikipedia.org/wiki/EOS_(medical_imaging)

    EOS is a medical imaging system designed to provide frontal and lateral radiography images, while limiting the X-ray dose absorbed by the patient in a sitting or standing position. The system relies on the high sensitivity of a detector ( multi-wire chamber ) invented by Georges Charpak , which earned him the 1992 Nobel Prize .

  8. Orbital x-ray - Wikipedia

    en.wikipedia.org/wiki/Orbital_x-ray

    The x-ray is taken PA (postero-antero), meaning that the patient faces towards the receiver and away from the x-rays source. The patients chin rests on the image receiver, which tilts the head up allowing the orbits to be clear of the internal structure of the Petrous ridge. This view is called Occipital-Mental or OM. [1] [2]

  9. Isocentric technique - Wikipedia

    en.wikipedia.org/wiki/Isocentric_technique

    The idealized intersection point of the gantry axis of rotation with that of the collimator and treatment table is known as the mechanical isocenter [2]. In practice, due to the heavy weight and mechanical imperfections of the system, the isocenter is not a single point and its location changes with the rotation of the gantry, collimator or couch.