enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    This formula was derived in 1744 by the Swiss mathematician Leonhard Euler. [2] The column will remain straight for loads less than the critical load. The critical load is the greatest load that will not cause lateral deflection (buckling). For loads greater than the critical load, the column will deflect laterally.

  3. Deflection (engineering) - Wikipedia

    en.wikipedia.org/wiki/Deflection_(engineering)

    Deflection (f) in engineering. In structural engineering, deflection is the degree to which a part of a long structural element (such as beam) is deformed laterally (in the direction transverse to its longitudinal axis) under a load.

  4. Cantilever method - Wikipedia

    en.wikipedia.org/wiki/Cantilever_method

    The cantilever method is an approximate method for calculating shear forces and moments developed in beams and columns of a frame or structure due to lateral loads. The applied lateral loads typically include wind loads and earthquake loads, which must be taken into consideration while designing buildings.

  5. Cantilever - Wikipedia

    en.wikipedia.org/wiki/Cantilever

    Like other structural elements, a cantilever can be formed as a beam, plate, truss, or slab. When subjected to a structural load at its far, unsupported end, the cantilever carries the load to the support where it applies a shear stress and a bending moment. [1] Cantilever construction allows overhanging structures without additional support.

  6. Energy release rate (fracture mechanics) - Wikipedia

    en.wikipedia.org/wiki/Energy_release_rate...

    Double cantilever beam (DCB) specimen under tensile load. J-integral path for the DCB specimen under tensile load. Consider the double cantilever beam specimen shown in the figure, where the crack centered in the beam of height has a length of , and a load is applied to open the crack. Assume that the material is linearly-elastic and that the ...

  7. Four-point flexural test - Wikipedia

    en.wikipedia.org/wiki/Four-point_flexural_test

    in these formulas the following parameters are used: = Stress in outer fibers at midpoint, = load at a given point on the load deflection curve, = Support span, (mm) = Width of test beam, (mm) = Depth or thickness of tested beam, (mm)

  8. Ensco plc Orders New Premium Jackup for Early 2015 Delivery - AOL

    www.aol.com/news/2013-04-08-ensco-plc-orders-new...

    For premium support please call: 800-290-4726 more ways to reach us

  9. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...