Portable, or field pH meters, are handheld pH meters that are used to take the pH of a sample in a field or production site. [19] In-line or in situ pH meters, also called pH analyzers, are used to measure pH continuously in a process, and can stand-alone, or be connected to a higher level information system for process control. [20]
The bottom of a pH electrode balloons out into a round thin glass bulb. The pH electrode is best thought of as a tube within a tube. The inner tube contains an unchanging 1×10 −7 mol/L HCl solution. Also inside the inner tube is the cathode terminus of the reference probe.
Therefore, pH values on the different scales cannot be compared directly because of differences in the solvated proton ions, such as lyonium ions, which require an insolvent scale that involves the transfer activity coefficient of hydronium/lyonium ion. pH is an example of an acidity function, but others can be defined.
In and of themselves, pH indicators are usually weak acids or weak bases. The general reaction scheme of acidic pH indicators in aqueous solutions can be formulated as: HInd (aq) + H 2 O (l) ⇌ H 3 O + (aq) + Ind − (aq) where, "HInd" is the acidic form and "Ind −" is the conjugate base of the indicator. Vice versa for basic pH indicators ...
Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition.
Pourbaix diagram of iron. [1] The Y axis corresponds to voltage potential. In electrochemistry, and more generally in solution chemistry, a Pourbaix diagram, also known as a potential/pH diagram, E H –pH diagram or a pE/pH diagram, is a plot of possible thermodynamically stable phases (i.e., at chemical equilibrium) of an aqueous electrochemical system.
Each instrument used in analytical chemistry has a useful working range. This is the range of concentration (or mass) that can be adequately determined by the instrument, where the instrument provides a useful signal that can be related to the concentration of the analyte. [1] All instruments have an upper and a lower working limit.
Intracellular pH (pH i) is the measure of the acidity or basicity (i.e., pH) of intracellular fluid. The pH i plays a critical role in membrane transport and other intracellular processes. In an environment with the improper pH i , biological cells may have compromised function.