A UV-Vis spectrophotometer is an analytical instrument that measures the amount of ultraviolet (UV) and visible light that is absorbed by a sample. It is a widely used technique in chemistry, biochemistry, and other fields, to identify and quantify compounds in a variety of samples.
In modern spectrographs in the UV, visible, and near-IR spectral ranges, the spectrum is generally given in the form of photon number per unit wavelength (nm or μm), wavenumber (μm −1, cm −1), frequency (THz), or energy (eV), with the units indicated by the abscissa.
Ultraviolet-visible (UV-vis) spectroscopy involves energy levels that excite electronic transitions. Absorption of UV-vis light excites molecules that are in ground-states to their excited-states. [5] Visible region 400–700 nm spectrophotometry is used extensively in colorimetry science. It is a known fact that it operates best at the range ...
Ultraviolet–visible spectroscopy (UV–vis) can distinguish between enantiomers by showing a distinct Cotton effect for each isomer. UV–vis spectroscopy sees only chromophores, so other molecules must be prepared for analysis by chemical addition of a chromophore such as anthracene.
For UV-Vis spectroelectrochemistry, spectrometer must be specific for UV-Vis spectral region. Potentiostat / Galvanostat : electronic device that allows controlling the working electrode potential regarding to the reference electrode or controlling the current that passes respect to the auxiliary electrode .
The vast majority of liquid chromatographic systems are equipped with ultraviolet (UV) absorption detectors. The most common UV-Vis detectors used are variable wavelength detectors (VWD), photo diode array detectors (PDA), and diode array detectors (DAD). [4] Variable wavelength detectors decide in advance which wavelength is needed for the ...
The DU was developed at National Technical Laboratories (later Beckman Instruments) under the direction of Arnold Orville Beckman, an American chemist and inventor. [13] [14] Beginning in 1940, National Technical Laboratories developed three in-house prototype models (A, B, C) and one limited distribution model (D) before moving to full commercial production with the DU in 1941.
If Albert Einstein's photoelectric law is applied to a free molecule, the kinetic energy of an emitted photoelectron is given by =, where h is the Planck constant, ν is the frequency of the ionizing light, and I is an ionization energy for the formation of a singly charged ion in either the ground state or an excited state.