The supply transformer (T) secondary winding is connected across the primary tuned circuit. It might seem that the transformer would be a leakage path for the RF current, damping the oscillations. However its large inductance gives it a very high impedance at the resonant frequency, so it acts as an open circuit to the oscillating current.
In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...
Shunt and series impedance network through a step-up transformer. These transforms do not just apply to single elements; entire networks can be passed through the transformer. In this manner, the transformer can be shifted around the network to a more convenient location.
A further transient problem is that with a single coil construction and a star switch, the autotransformer acts as a step-up transformer during the <5 microsecond period at contact separation of the Star point switch. With the motor connected to the 80% voltage tap there will be an escalation of the transient by 5:1 ratio.
A boost converter or step-up converter is a DC-to-DC converter that increases voltage, while decreasing current, from its input to its output . It is a class of switched-mode power supply (SMPS) containing at least two semiconductors, a diode and a transistor , and at least one energy storage element: a capacitor , inductor , or the two in ...
The concept that is the basis of modern transmission using inexpensive step up and step down transformers was first implemented by Westinghouse, William Stanley, Jr. and Franklin Leonard Pope in 1886 in Great Barrington, Massachusetts, resorting also to European technology.
Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...
In a step-up transformer, conversely, the load is attached across the full winding while the source is connected to a tap across a portion of the winding. For a step-up transformer, the subscripts in the above equations are reversed where, in this situation, N 2 {\displaystyle N_{2}} and V 2 {\displaystyle V_{2}} are greater than N 1 ...