External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...
In firefighting, the policy of two-in, two-out refers to United States Occupational Safety and Health Administration (OSHA) policy 29 CFR 1910.134(g)(4)(i). [1] The respiratory protection standard requires that workers engaged in fighting interior structural fires work in a buddy system; at least two workers must enter the building together, so that they can monitor each other's whereabouts as ...
Sprinkler systems installed by sprinkler fitters can include the underground supply as well as integrated overhead piping systems and standpipes. The fire suppression piping may contain water, air (in a dry system), antifreeze, gas or chemicals as in a hood system, or a mixture producing fire retardant foam.
The primary fire code writing organization is the private National Fire Protection Association or NFPA. NFPA sets the standards for technical aspects of sprinklers installed in the USA. Building codes, which specify which buildings require sprinklers are generally left to local jurisdictions. However, there are some exceptions:
Standpipes are installed in most large, multistory buildings. There are two types of standpipes: dry and wet. Most standpipes are dry systems and cannot be used by the public. Dry systems require a fire engine to pump water into the system. Most dry systems do not have pre-connected hoses and require firefighters to bring in the hose.
Compare "standpipe". Hydrant assist valve A valve connected to the hydrant by the first due engine allowing the second due engine to boost the pressure in the intake line. Used for hydrants with low pressure, attaching multiple engines to one hydrant, or boosting pressure in the intake line to accommodate for friction loss. Hydrant gate
The Life Safety Code is coordinated with hundreds of other building codes and standards such as National Electrical Code NFPA 70, fuel-gas, mechanical, plumbing (for sprinklers and standpipes), energy and fire codes. Normally, the Life Safety Code is used by architects and designers of vehicles and vessels used for human occupancy.
Standards set by the National Fire Protection Association require that each length of new double jacket, rubber-lined attack hose must be pressure tested to 600 psi (41.4 bar; 4,140 kPa), but most manufacturers test to 800 psi (55.2 bar; 5,520 kPa). Subsequent to delivery, the hose is tested annually to 400 psi (27.6 bar; 2,760 kPa) by the fire ...