  2. Transformer oil testing - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil_testing

    The lower the resulting breakdown voltage, the poorer the quality of the transformer oil. The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil. A test voltage is applied to the electrodes and is continuously increased up ...

  3. Transformer oil - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil

    To determine the insulating property of the dielectric oil, an oil sample is taken from the device under test, and its breakdown voltage is measured on-site according to the following test sequence: In the vessel, two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the insulating oil.

  4. Liquid dielectric - Wikipedia

    en.wikipedia.org/wiki/Liquid_dielectric

    Dielectric constant Max. breakdown strength (MV ⁄ cm) Properties Mineral oil: 1.0 [1] Flammable. Common type of transformer oil. n-Hexane: 1.1–1.3 [1] Flammable. Used in some capacitors. n-Heptane: Flammable. Castor oil natural ester 4.7: High dielectric constant. Flammable. Refined and dried castor oil is used in some high voltage capacitors.

  5. Electrical breakdown - Wikipedia

    en.wikipedia.org/wiki/Electrical_breakdown

    Electrical breakdown in an electric discharge showing the ribbon-like plasma filaments from a Tesla coil.. In electronics, electrical breakdown or dielectric breakdown is a process that occurs when an electrically insulating material (a dielectric), subjected to a high enough voltage, suddenly becomes a conductor and current flows through it.

  6. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    In electrical engineering, a dielectric withstand test (also pressure test, high potential test, hipot test, or insulation test) is an electrical safety test performed on a component or product to determine the effectiveness of its insulation. The test may be between mutually insulated sections of a part, or energized parts and ground.

  7. Dielectric strength - Wikipedia

    en.wikipedia.org/wiki/Dielectric_strength

    Dielectric films tend to exhibit greater dielectric strength than thicker samples of the same material. For instance, the dielectric strength of silicon dioxide films of thickness around 1 μm is about 0.5 GV/m. [3] However very thin layers (below, say, 100 nm) become partially conductive because of electron tunneling.

  8. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Transformer in-service interruptions and failures usually result from dielectric breakdown, winding distortion caused by short circuits, hots spots caused by localized deviations in winding and electromagnetic fields, deterioration of insulation, effects of lightning and other electrical disturbances, inadequate maintenance, loose connections ...

  9. Dissolved gas analysis - Wikipedia

    en.wikipedia.org/wiki/Dissolved_gas_analysis

    An oil sample tube is used to draw, retain and transport the sample of transformer oil in the same condition as it is inside a transformer with all fault gases dissolved in it. It is a gas tight borosilicate glass tube of capacity 150 ml or 250 ml, having two airtight Teflon valves on both the ends. The outlets of these valves have been ...