enow.com Web Search

  1. Ads

    related to: biventricular pacing ecg

Search results

  1. Results from the WOW.Com Content Network
  2. Artificial cardiac pacemaker - Wikipedia

    en.wikipedia.org/wiki/Artificial_cardiac_pacemaker

    Dual-chamber pacemaker. Here, wires are placed in two chambers of the heart. One lead paces the atrium and one paces the ventricle. This type more closely resembles the natural pacing of the heart by assisting the heart in coordinating the function between the atria and ventricles. [10] Biventricular pacemaker. This pacemaker has three wires ...

  3. Ventricular dyssynchrony - Wikipedia

    en.wikipedia.org/wiki/Ventricular_dyssynchrony

    All three presentations allow distinct and easily reproducible electrical signatures as illustrated by left and right bundle branch blocks, hemiblocks, etc. The concise measurement of the time and morphology of the QRS interval allows the interventional ability to manipulate this interval with biventricular pacemakers.

  4. Cardiac resynchronization therapy - Wikipedia

    en.wikipedia.org/wiki/Cardiac_resynchronization...

    Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.

  5. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles. [citation needed]

  6. Heart failure - Wikipedia

    en.wikipedia.org/wiki/Heart_failure

    Using a special pacing algorithm, biventricular cardiac resynchronization therapy (CRT) can initiate a normal sequence of ventricular depolarization. In people with LVEF below 35% and prolonged QRS duration on ECG (LBBB or QRS of 150 ms or more), an improvement in symptoms and mortality occurs when CRT is added to standard medical therapy. [122]

  7. Clinical cardiac electrophysiology - Wikipedia

    en.wikipedia.org/wiki/Clinical_cardiac...

    Electrophysiology study (EPS) consists in the insertion of pacing and recording electrodes either in the esophagus (intra-esophageal EPS) or, through blood vessels, directly into the heart chambers (intra-cardiac EPS) in order to measure electrical properties of the heart and, in the case of intra-cardiac EPS, to electrically stimulate it in ...

  1. Ads

    related to: biventricular pacing ecg