enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Airflow window - Wikipedia

    en.wikipedia.org/wiki/Airflow_window

    An airflow window is composed of at least two panes of glass and a cavity between them that allows the flow of ventilation air. They operate on similar principles to a double-skin facade, but on a smaller scale. [1] [2] The general idea is to improve the energy efficiency of a cavity window by heating or cooling the cavity with ventilation air.

  3. Cross ventilation - Wikipedia

    en.wikipedia.org/wiki/Cross_ventilation

    Cross-breezes work when two windows are opposite of each other. Cross ventilation is a natural phenomenon where wind, fresh air or a breeze enters upon an opening, such as a window, and flows directly through the space and exits through an opening on the opposite side of the building (where the air pressure is lower).

  4. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The hourly ventilation rate divided by the volume of a space. For perfectly mixed air or laminar flow spaces, this is equal to the number of times per hour that the volume the space is exchanged by mechanical and natural ventilation. Also called air change rate or air exchange rate. Abbreviated ACH or ac/hr. air conditioner

  5. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Air can be exhausted through pressurized hoods or the use of fans and pressurizing a specific area. [35] A local exhaust system is composed of five basic parts: A hood that captures the contaminant at its source; Ducts for transporting the air; An air-cleaning device that removes/minimizes the contaminant; A fan that moves the air through the ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. [32] (Minisplit ...

  7. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Schematic flow diagram of calculation procedure showing transformation from cooling load calculated for an overhead mixing system into a UFAD cooling load, and then divided between the supply plenum, zone (room), and return plenum.

  8. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Air conditioning, often abbreviated as A/C (US) or air con (UK), [1] is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature and in some cases also controlling the humidity of internal air. Air conditioning can be achieved using a mechanical 'air conditioner' or by other methods, including ...

  9. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.