DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
The closed loop system can be more effective cooling the air (during air temperature extremes) than an open system, since it cools and recools the same air. Open system: Outside air is drawn from a filtered air intake (Minimum Efficiency Reporting Value MERV 8+ air filter is recommended) to cool or preheat the air. The tubes are typically 30 m ...
AMCA Publication 200 - Air Systems. Part 1 of the Fan Application Manual, this publication provides basic information necessary for the design of energy efficient air systems. This edition includes examples in both the Inch-Pound and SI systems as the reader is provided with basic information on air systems. AMCA Publication 201 - Fans and ...
DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...
There is a pressure difference between the outside air and the air inside the building caused by the difference in temperature between the outside air and the inside air. That pressure difference ( ΔP ) is the driving force for the stack effect and it can be calculated with the equations presented below.
Standard HVAC system design uses fixed airflow rates to calculate the outdoor air (OA) required in a space. These airflow rates are determined by mechanical code and vary based on expected occupancy and space use. [2] This process of supplying fixed airflow to a space ensures that sufficient OA is present in that space when it is occupied.
Dr. Jeremy London, shown above, is a cardiovascular surgeon in Savannah, Georgia. He shared some strong thoughts about red wine and the heart.
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...