enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  3. Moisture removal efficiency - Wikipedia

    en.wikipedia.org/wiki/Moisture_removal_efficiency

    DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...

  4. Demand controlled ventilation - Wikipedia

    en.wikipedia.org/wiki/Demand_controlled_ventilation

    Standard HVAC system design uses fixed airflow rates to calculate the outdoor air (OA) required in a space. These airflow rates are determined by mechanical code and vary based on expected occupancy and space use. [2] This process of supplying fixed airflow to a space ensures that sufficient OA is present in that space when it is occupied.

  5. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  7. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    AMCA Publication 201 - Fans and Systems. Part 2 of the Fan Application Manual, discusses the effect of inlet and outlet connections on fan performance. It includes separate axial fan factors and is aimed primarily at the designer of the air moving system. AMCA Publication 202 - Troubleshooting. Part 3 of the Fan Application Manual, helps to ...

  8. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other purposefully designed openings or containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor air density resulting from temperature and moisture differences ...

  9. Ground-coupled heat exchanger - Wikipedia

    en.wikipedia.org/wiki/Ground-coupled_heat_exchanger

    Single-pass earth air heat exchangers offer the potential for indoor air quality improvement over conventional systems by providing an increased supply of outdoor air. In some configurations of single-pass systems, a continuous supply of outdoor air is provided. This type of system would usually include one or more ventilation heat recovery units.