The representation is made on a temperature-relative humidity, instead of a standard psychrometric chart. The comfort zone in blue represents the 90% of acceptability, which means the conditions between -0.5 and +0.5 PMV, or PPD < 10%.
When the temperature is 30 °C (86 °F) and the dew point is 15 °C (59 °F), the humidex is 34. If the temperature remains 30 °C (86 °F) and the dew point rises to 25 °C (77 °F), the humidex rises to 42. The humidex is higher than the U.S. heat index at equal temperature and relative humidity. The humidex formula is as follows: [7] [8]
For example, according to the heat index, a relative humidity of 75% at air temperature of 80.0 °F (26.7 °C) would feel like 83.6 ± 1.3 °F (28.7 ± 0.7 °C). [13] [14] Relative humidity is also a key metric used to evaluate when it is appropriate to install flooring over a concrete slab. [clarification needed]
Determining the effect of temperature change on relative humidity: For air of a fixed water composition or moisture ratio, find the starting relative humidity from the intersection of the wet and dry bulb temperature lines. Using the conditions from the previous example, the relative humidity at a different dry bulb temperatures can be found ...
The results are displayed on a psychrometric or a temperature-relative humidity chart and indicate the ranges of temperature and relative humidity that will be comfortable with the given the values input for the remaining four parameters. [44] The PMV/PPD model has a low prediction accuracy. [45]
using Plots # Saturated water vapor pressure [Pa] # See Ham, 2005. Useful Equations and Tables in Micrometeorology function water_vapor_saturated_pressure (Ta, P) Ta = Ta-273.15 es = (1.0007 + (3.46e-5 * (P / 1e3))) * 0.61121 * exp ((17.502 * Ta) / (Ta + 240.97)) * 1e3 return es end function water_vapor_density (e, Tair) Rs_v = 461.5 # J/(kg.K) specific gas constant for water vapor ρv = e ...
Apparent temperature, also known as "feels like", [1] [2] is the temperature equivalent perceived by humans, caused by the combined effects of air temperature, relative humidity and wind speed. The measure is most commonly applied to the perceived outdoor temperature.
The relationship between water content and equilibrium relative humidity of a material can be displayed graphically by a curve, the so-called moisture sorption isotherm. For each humidity value, a sorption isotherm indicates the corresponding water content value at a given temperature. If the composition or quality of the material changes, then ...