enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    Airtightness of components ranges from class A to D, with class A being the leakiest one. EN 1751 [4] and EN 15727 [5] specify the leakage requirements for technical ductwork components and are based on the same leakage classification. Airtightness classes for air handling units (L1 to L3) are defined in EN 1886. [6]

  3. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    In cold climates, with a 15 MPH wind, residences often have air exchange rates of 1.0 to 1.5 ACHs, far in excess of the ventilation air needs and are thus called loose construction. It is very easy to reduce infiltration rates to less than 1.0 ACH. Smoke candles and blower-door tests can help identify less-than-obvious leaks.

  4. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  5. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n

  6. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    AMCA Publication 99 - Standards Handbook is a compilation of important AMCA standards that include the Fan Laws, common industry terminology and symbols, classifications for spark resistant construction, and various other useful data. AMCA Publication 200 - Air Systems. Part 1 of the Fan Application Manual, this publication provides basic ...

  7. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  8. Bitter cold winter temperatures are on their way out, but ...

    www.aol.com/bitter-cold-winter-temperatures-way...

    Frigid, then mild. After wind chills dipped below zero across the mountains of the Appalachians Friday, conditions are expected to improve through the next couple of days as southwesterly winds ...

  9. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Leakage in UFAD supply plenums can be a major cause for inefficiency in a UFAD system. There are two types of leakageleakage into the space and leakage into pathways that bypass the space. The first category of leakage does not result in an energy penalty because air is getting to the zone it is intended to cool.