  1. Results from the WOW.Com Content Network
  2. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  3. Linear heat detection - Wikipedia

    en.wikipedia.org/wiki/Linear_Heat_Detection

    Linear heat detection (LHD) cable is essentially a two-core cable terminated by an end-of-line resistor (resistance varies with application). The two cores are separated by a polymer plastic, that is designed to melt at a specific temperature (commonly 68 °C for building applications [1]), and without which causes the two cores to short.

  4. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  5. EN 54 - Wikipedia

    en.wikipedia.org/wiki/EN_54

    The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.

  6. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    In that case, the wire is not tri-rated. According to UL 758, the maximum operating temperature of tri-rated cable is 105 °C. British Standard BS 6231 requires only a maximum operating temperature of 90 °C for continuous use. UL and CSA give tri-rated cable a voltage rating of 600 V, while it is rated at 1000 V in the BS 6231 standard.

  7. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.

  8. Aaron Rodgers Is ‘a Very Difficult Person to Understand ...

    www.aol.com/aaron-rodgers-very-difficult-person...

    PEOPLE spoke with the directors behind Netflix's new docuseries 'Aaron Rodgers: Enigma,' which began streaming Tuesday

  9. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60055 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) IEC 60059 IEC standard current ratings; IEC 60060 High-voltage test techniques; IEC 60061 Lamp caps and holders together with gauges for the control of interchangeability and safety