Search results
Results from the WOW.Com Content Network
This volume of natural gas has the same energy content as one US gallon of gasoline (based on lower heating values: 900 BTU/cu ft (9.3 kWh/m 3) of natural gas and 114,000 BTU/US gal (8.8 kWh/L) for gasoline). [22] One GGE of CNG pressurized at 2,400 psi (17 MPa) is 0.77 cubic feet (22 litres; 5.8 US gallons).
The Btu should not be confused with the Board of Trade Unit (BTU), an obsolete UK synonym for kilowatt hour (1 kW⋅h or 3,412 Btu). The Btu is often used to express the conversion-efficiency of heat into electrical energy in power plants. Figures are quoted in terms of the quantity of heat in Btu required to generate 1 kW⋅h of electrical energy.
The therm (symbol, thm) is a non-SI unit of heat energy equal to 100,000 British thermal units (BTU), [1] and approximately 105 megajoules, 29.3 kilowatt-hours, 25,200 kilocalories and 25.2 thermies. One therm is the energy content of approximately 100 cubic feet (2.83 cubic metres) of natural gas at standard temperature and pressure .
BTU IT /h ≡ 1 BTU IT /h ≈ 0.293 071 W: BTU (International Table) per minute: BTU IT /min ≡ 1 BTU IT /min ≈ 17.584 264 W: BTU (International Table) per second: BTU IT /s ≡ 1 BTU IT /s = 1.055 055 852 62 × 10 3 W: calorie (International Table) per second: cal IT /s ≡ 1 cal IT /s = 4.1868 W: erg per second: erg/s ≡ 1 erg/s = 10 −7 ...
Yet other definitions are in use for industrial gas, [5] where, in the US, a standard cubic foot for industrial gas use is defined at 70 °F (21.1 °C) and 14.696 psia (101.325 kPa), while in Canada, a standard cubic meter for industrial gas use is defined at 15 °C (59 °F) and 101.325 kPa (14.696 psia).
If the system were moving a gas at exactly the "standard" condition, then ACFM would equal SCFM. This usually is not the case as the most important change between these two definitions is the pressure. To move a gas, a positive pressure or a vacuum must be created. When positive pressure is applied to a standard cubic foot of gas, it is compressed.
The Wobbe index is expressed in MJ/Nm³ (where 'Nm³' indicates'm³ in Normal conditions), or sometimes in BTU/scf.In the case of natural gas (molar mass 17 g/mol), the typical heating value is around 39 MJ/Nm³ (1,050 BTU/scf) and the specific gravity is approximately 0.59, giving a typical Wobbe index of 51 MJ/Nm³ (1,367 BTU/scf).
V m = 10.7316 × 519.67 / 14.730 = 378.61 ft 3 /lbmol at 60 °F and 14.73 psi; Technical literature can be confusing because many authors fail to explain whether they are using the ideal gas constant R, or the specific gas constant R s. The relationship between the two constants is R s = R / m, where m is the molecular mass of the gas.