Time response is measured by immersing the sensor in water moving at 1 m/s (3.3 ft/s) with a 63.2% step change. Size A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements
The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.
The two top thermocouple junctions are at temperature T 1 while the two bottom thermocouple junctions are at temperature T 2. The output voltage from the thermopile, ΔV , is directly proportional to the temperature differential, ΔT or T 1 - T 2 , across the thermal resistance layer and number of thermocouple junction pairs.
Figure 2: [8] Working principle of a thermal laser sensor (Adapted from figure 3 with permission) As shown in Fig 2, a thermopile laser sensor consists of several thermocouples connected in series with one junction type (hot junction at temperature T 1) being exposed to an absorption area and the other junction type (cold junction at temperature T 2) being exposed to a heat sink.
The heat generated dissipates into the sample on both sides of the sensor, at a rate depending on the thermal transport properties of the material. By recording temperature vs. time response in the sensor, the thermal conductivity, thermal diffusivity and specific heat capacity of the material can be calculated.
Response time – the time required to measure 63.2% of the total difference between its initial and final temperature when subjected to a step function change in temperature; other points such as 90% are also used. [2] shock and vibration resistance; Water resistance – humidity, condensation, etc. Size, weight, mounting
An example response of system to sine wave forcing function. Time axis in units of the time constant τ. The response damps out to become a simple sine wave. Frequency response of system vs. frequency in units of the bandwidth f 3dB. The response is normalized to a zero frequency value of unity, and drops to 1/√2 at the bandwidth.
Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.