If the arm electrodes are reversed, lead I changes polarity, causing lead II and lead III to switch. If the right arm electrode is reversed with the leg's electrode, lead II changes polarity, causing lead I to become lead III, and vice versa. Reversal of the left arm and leg causes a change in polarity of lead III and switching of leads I and ...
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...
In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).
English: The twelve leads of a twelve-lead electrocardiogram are shown here with the contiguous leads shown in the same color: Pink — aVR; Orange — septal leads (V1, V2) Yellow — inferior leads (II, III, aVF) Green — lateral leads (I, aVL, V5, V6) Blue — anterior leads (V3, V4)
The V 5 ECG lead is placed on the anterior axillary line, horizontally even with V 4. The midaxillary line is a coronal line on the torso between the anterior and posterior axillary lines. It is a landmark used in thoracentesis, [2] and the V6 electrode of the 10 electrode ECG.
If lead b is positive, the electrical heart axis can be estimated to lie within the quadrant between axis of lead a and lead b. A simple tool to quickly identify axis deviation (Figure 3) is the popular mnemonic; R eaching for R ight Axis Deviation and L eaving for L eft Axis Deviation.
Wandering atrial pacemaker (WAP) is an atrial rhythm where the pacemaking activity of the heart originates from different locations within the atria. [1] This is different from normal pacemaking activity, where the sinoatrial node (SA node) is responsible for each heartbeat and keeps a steady rate and rhythm.
A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG. In order to create the Lewis Lead, the right arm electrode is moved to the manubrium adjacent to the sternum ...