The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Vernier micrometer reading 5.783 ± 0.001 mm, comprising 5.5 mm on main screw lead scale, 0.28 mm on screw rotation scale, and 0.003 mm added from vernier. Some micrometers are provided with a vernier scale on the sleeve in addition to the regular graduations. These permit measurements within 0.001 millimetre to be made on metric micrometers ...
MSA analyzes the collection of equipment, operations, procedures, software and personnel that affects the assignment of a number to a measurement characteristic. A measurement system analysis considers the following: Selecting the correct measurement and approach; Assessing the measuring device; Assessing procedures and operators
For example, ISO 1502 sets a standard for screw threads and gauging to test them. It establishes the attribute T as go for the major diameter and the attribute Z as no-go for the pitch diameter. [1] The inspection tool has two threaded components. For example, there would be two female sections on a gauge to test a threaded male workpiece such ...
A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Clap-o-meter; Class of accuracy in electrical measurements; Clifton nanolitre osmometer; Clinometer; Cole's quadrant; Compressometer; Constant fraction discriminator; Continuous-scan laser Doppler vibrometry; Corrosion monitoring; Cover meter; Creep-testing machine; Creepmeter; Cross bow quadrant; Current clamp; Cylindrical coordinate measuring ...