enow.com Web Search

  1. Ad

    related to: infinity cat5e outdoor cable switch wiring instructions printable

Search results

  1. Results from the WOW.Com Content Network
  2. Structured cabling - Wikipedia

    en.wikipedia.org/wiki/Structured_cabling

    Regardless of copper cable type (Cat 5e/6/6A), the maximum distance is 90 m for the permanent link installation, plus an allowance for a combined 10 m of patch cords at the ends. Cat 5e and Cat 6 can both effectively run power over Ethernet (PoE) applications up to 90 m. However, due to greater power dissipation in Cat 5e cable, performance and ...

  3. Category 5 cable - Wikipedia

    en.wikipedia.org/wiki/Category_5_cable

    The cable is available in both stranded and solid conductor forms. The stranded form is more flexible and withstands more bending without breaking. Patch cables are stranded. Permanent wiring used in structured cabling is solid. The category and type of cable can be identified by the printing on the jacket. [6]

  4. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    A cable terminated according to T568A on one end and T568B on the other is a crossover cable when used with the earlier twisted-pair Ethernet standards that use only two of the pairs because the pairs used happen to be pairs 2 and 3, the same pairs on which T568A and T568B differ. Crossover cables are occasionally needed for 10BASE-T and ...

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Specific exceptions apply, such as a cable running to a switch and back (known as a traveler) where the white wire will be the hot wire feeding that switch. Another is for a cable used to feed an outlet for 250 VAC appliances that do not need a neutral, there the white is hot. In both those instances the white wire should be identified as being ...

  6. Ethernet crossover cable - Wikipedia

    en.wikipedia.org/wiki/Ethernet_crossover_cable

    This wiring scheme constitutes a crossover cable. A crossover cable may also be used to connect two hubs or two switches on their upstream ports. Because the only difference between the T568A and T568B pin and pair assignments are that pairs 2 and 3 are swapped, a crossover cable may be envisioned as a cable with one modular connector following ...

  7. IDC (electrical connector) - Wikipedia

    en.wikipedia.org/wiki/IDC_(electrical_connector)

    Pin 1 is typically indicated on the body of the connector by a red or raised "V" mark. The corresponding wire in a ribbon cable is usually indicated by red coloration, a raised molded ridge, or markings printed onto the cable insulation. On the connector pin 2 is opposite pin 1, pin 3 is next to pin 1 along the length of the connector, and so on.

  8. Copper cable certification - Wikipedia

    en.wikipedia.org/wiki/Copper_cable_certification

    The significance of each category or class is the limit values of which the Pass/Fail and frequency ranges are measured: Cat 3 and Class C (no longer used) test and define communication with 16 MHz bandwidth, Cat 5e and Class D with 100 MHz bandwidth, Cat 6 and Class E up to 250 MHz, Cat6A and Class EA up to 500 MHz, Cat7 and Class F up to 600 ...

  9. Infinite switch - Wikipedia

    en.wikipedia.org/wiki/Infinite_switch

    An early switch operating by this principle was invented by Chester I. Hall of the General Electric Company, with a patent filed in 1921 and approved in 1924.Like the modern infinite switch, Hall's invention used a bi-metallic strip, heated by a constant current, to break a connection after a given period of time.

  1. Ad

    related to: infinity cat5e outdoor cable switch wiring instructions printable